Product Overview
Vertical Bitumen Tanks are industrial storage tanks used to store and heat paving-grade bitumen for asphalt mixing plants, road construction projects and bitumen terminals. Tank capacity, heating configuration, insulation and discharge arrangements can be selected according to storage demand, site conditions and the required operating temperature.
Space-Efficient Layout
The vertical configuration can reduce the tank footprint compared with some horizontal storage arrangements. Actual space requirements depend on tank dimensions, foundation design and site layout.
Controlled Bitumen Heating
Thermal oil, electric heating or other project-specific heating arrangements can be selected according to the bitumen grade, target temperature and available site utilities.
Insulated Tank Construction
Thermal insulation and external cladding can be specified to suit the local climate, heat-loss requirements and installation environment.
Configured Material Discharge
Bottom outlets, transfer pumps, valves and heated piping can be arranged according to the required discharge flow and downstream equipment.
-
Heavy Duty Vertical Bitumen TankA Heavy Duty Vertical Bitumen Tank stores hot bitumen for asphalt production and industrial storage operations. Capacity, heating arrangements, insulation, instrumentation and connections can be
-
Insulated Vertical Bitumen SiloAn insulated vertical bitumen silo stores hot bitumen for asphalt production, road construction, and bulk bitumen handling. Thermal insulation helps reduce heat loss, while an optional heating system
-
Vertical Bitumen Tank With Heating CoilsA vertical bitumen storage tank with internal heating coils stores paving-grade bitumen and maintains its temperature for asphalt production, road construction, and bitumen processing. The tank
-
Stationary Vertical Asphalt TankA Stationary Vertical Asphalt Storage Tank is designed to store paving bitumen and specified grades of polymer-modified bitumen at controlled temperatures before transfer to asphalt mixing or road
-
Space Saving Vertical Bitumen Storage TankA Space-Saving Vertical Bitumen Storage Tank stores bitumen at a specified operating temperature in a vertical tank configuration. It is suitable for asphalt mixing plants, road construction
-
Thermal Oil Heated Vertical Bitumen TankA vertical bitumen storage tank with indirect thermal oil heating stores bitumen at a specified operating temperature for asphalt production and bulk handling. Thermal oil circulates through an
Tank Configurations & Selection
Storage Capacity
Select tank capacity based on daily bitumen consumption, delivery frequency, required reserve stock and replenishment schedule. Usable operating volume should be distinguished from total geometric capacity.
Tank Structure & Installation
Foundation Requirements: Foundation design should account for tank dimensions, empty and full operating weight, ground conditions and applicable environmental loads.
Access & Maintenance: Ladders, platforms, inspection openings and maintenance access can be specified according to the installation layout and applicable safety requirements.
Heating System Options
Thermal Oil Heating: Indirect heating through heating coils, with the heating duty and coil arrangement determined by the required temperature profile and bitumen properties.
Electric Heating: Suitable where the available electrical supply, heating load and operating requirements support the proposed configuration.
Steam or Other Heating Arrangements: Available for evaluation where compatible with the project design and site utilities.
Insulation & Temperature Control
Insulation: Rock wool or another specified insulation material, with thickness selected according to ambient temperature and heat-loss requirements.
External Cladding: Aluminum, galvanized steel or coated steel, subject to the project specification.
Temperature Monitoring: Temperature sensors, digital indicators and high- or low-temperature alarms can be included according to the control requirements.
Technical Specifications
The following values are indicative selection ranges based on the proposed product configuration. Final specifications must be confirmed against the actual product design and project requirements.
|
Parameter |
Indicative Specification |
Customization Options |
|
Tank Type |
Vertical bitumen storage tank |
Project-specific layout |
|
Nominal Capacity |
20–100 m³ per tank |
Larger capacities subject to engineering review |
|
Tank Material |
Carbon steel |
Other materials subject to compatibility review |
|
Operating Temperature |
Project-specific |
Determined by bitumen grade and process requirements |
|
Heating Method |
Thermal oil or electric heating |
Steam or combined arrangements subject to review |
|
Insulation |
Rock wool or specified insulation material |
Thickness based on thermal design |
|
Outer Cladding |
Coated steel or aluminum |
Material and thickness by specification |
|
Discharge |
Bottom outlet with pump-assisted transfer where required |
Outlet size, valves and pump configuration |
|
Temperature Control |
Sensors and digital indicators |
Alarm functions and PLC integration |
|
Inspection & Documentation |
Project-specific inspection plan |
Material certificates, inspection records and agreed test reports |
Heating, Insulation & Discharge Design
Heating Duty Calculation
Heating requirements depend on the bitumen mass, initial temperature, target temperature, required heating time, heat losses and heating medium. The heating system should be sized using these project conditions rather than tank capacity alone.
Temperature Management
Sensor locations, control ranges and alarm settings should reflect the selected bitumen grade and operating procedure. Heating and circulation requirements for polymer-modified bitumen must be confirmed for the specific formulation.
Heat-Loss Control
Insulation thickness and external cladding are selected according to ambient conditions, heat-loss targets and site requirements. Actual energy consumption depends on the tank design, operating schedule, heating system and environmental conditions.
Discharge & Transfer
Outlet geometry, pump capacity, valve selection and piping arrangements should be matched to the required flow rate and bitumen temperature. Pipe and valve heating or insulation can be specified where necessary to maintain transfer conditions.
Material Verification
Steel grade, plate thickness and material documentation are checked against the approved bill of materials and project requirements. Material certificates and traceability records can be supplied where included in the agreed scope.
Welding & Fabrication
Welding procedures, welder qualifications and inspection requirements are established according to the applicable project specifications and approved fabrication documents.
Dimensional & Visual Inspection
Tank dimensions, nozzle positions, connections, accessories and surface condition are checked against approved drawings and inspection criteria.
Weld Inspection & Testing
Non-destructive testing and leak or integrity testing are performed where required by the approved design, applicable standards and inspection plan. Third-party inspection can be arranged by agreement.
Documentation
Available handover documents may include material certificates, inspection records, applicable test reports, equipment drawings and operation and maintenance instructions, as agreed in the purchase specification.

Applications & System Integration
Asphalt Mixing Plants
Configured to supply paving-grade bitumen to asphalt production systems according to the required storage volume, heating conditions and transfer rate.
Road Construction Projects
Suitable for project-specific bitumen storage and heating arrangements where on-site storage is required.
Bitumen Storage Terminals
Can be configured with transfer pumps, manifold piping, loading connections and monitoring systems according to terminal operating requirements.
Integration Requirements
Before equipment selection, confirm the available heating utilities, electrical supply, pipe routing, foundation loads, required transfer rate and compatibility with existing PLC or DCS controls. Interfaces such as 4–20 mA or Modbus should be specified where required.
Polymer-Modified Bitumen (PMB)
PMB storage requires confirmation of the material grade, operating temperature, circulation requirements and heating arrangement to help avoid unsuitable thermal exposure or material degradation.
Bitumen Emulsions
Emulsion storage requires a separately specified configuration based on the emulsion formulation and temperature requirements. High-temperature bitumen storage conditions should not be applied automatically to emulsions.
Customization & RFQ Requirements
To prepare a suitable technical proposal and preliminary General Arrangement (GA) drawing, provide the following information:
Project & Capacity
Required capacity per tank, total tank quantity, daily bitumen consumption and delivery frequency.
Bitumen & Operating Conditions
Bitumen grade, initial temperature, target storage temperature and expected ambient temperature range.
Heating & Insulation
Preferred heating medium, available utilities, required heating time and site climate.
Discharge & Integration
Required transfer flow rate, outlet size, pump requirements, piping arrangement and control interfaces.
Installation & Compliance
Installation location, foundation information, applicable design standards and required inspection documentation.
Commercial Requirements
Destination port, preferred delivery terms such as FOB or CIF, packaging requirements and target delivery schedule.
Submit the available project specifications and drawings for technical review. The quotation, configuration and delivery schedule can then be confirmed against the agreed scope.
Frequently Asked Questions
As one of the leading vertical bitumen tanks manufacturers and suppliers in China, we warmly welcome you to buy cheap vertical bitumen tanks from our factory. All customized products are with high quality and competitive price. Contact us for pricelist.

