Product Overview
 

Mobile Bitumen Tanks provide relocatable storage, heating and transfer of bitumen for road construction projects, mobile asphalt plants and temporary storage facilities.

Flexible Mobility Options

Trailer-mounted tanks support projects requiring frequent relocation, subject to destination transport regulations. Skid-mounted tanks suit temporary installations where lifting equipment is available.

Integrated Heating and Storage

Thermal oil coils or electric heating systems can be selected according to the required storage temperature, available energy supply and operating conditions.

Configurable Transfer System

Pump capacity, heated pipelines, valves and connection sizes can be specified according to bitumen viscosity, discharge temperature and downstream equipment requirements.

 
  • Portable Asphalt Transport And Storage Tank
    A Portable Asphalt Transport & Storage Tank is designed for transporting and temporarily holding hot bitumen between supply terminals, asphalt plants, and road construction sites. Configuration
  • Mobile Road Construction Bitumen Tank
    A Mobile Road Construction Bitumen Tank provides temporary or relocatable storage for paving bitumen at road construction sites, asphalt plants, and project depots. The system can be configured with
  • Trailer Mounted Bitumen Tank
    A Trailer Mounted Bitumen Tank is designed to transport hot bitumen from refineries, storage terminals, and asphalt plants to road construction sites. Tank capacity, heating configuration,
  • Portable Bitumen Storage And Heating Tank
    Portable Bitumen Storage and Heating Tanks provide temporary or supplementary storage for hot bitumen at road construction sites, asphalt plants, and bitumen handling facilities.
  • Chassis Mounted Mobile Bitumen Tank
    A chassis-mounted mobile bitumen tank is designed for transporting and temporarily holding bitumen for road paving, asphalt production and infrastructure projects. Tank capacity, chassis mounting,
  • Towing Type Mobile Bitumen Tank
    A Towing Type Mobile Bitumen Tank is used to store, heat and transfer bitumen at road construction sites, mobile asphalt plants and temporary infrastructure projects. Tank capacity, heating method,
 
Technical Specifications

 

The following values are indicative configuration options. Final specifications depend on the selected model, project requirements and confirmed engineering design.

 

Parameter

Indicative Specification

Customization Options

Nominal Capacity

30 m³ / 40 m³ / 50 m³ / 60 m³

Other capacities subject to design review

Tank Structure

Horizontal cylindrical tank

Compartment layout subject to application

Mounting Type

Trailer-mounted or skid-mounted

Chassis, lifting and support arrangements

Heating Method

Thermal oil heating or electric heating

Combined heating subject to engineering review

Thermal Insulation

100–150 mm rock wool

Thickness based on ambient conditions and holding requirements

External Cladding

Coated steel or stainless steel

Material and finish options

Operating Temperature

Project-specific; up to 200°C subject to design confirmation

Based on bitumen grade, seals and heating configuration

Electric Heating Power

Indicative range: 30–120 kW

Selected according to capacity and required heating time

Temperature Control

Temperature sensors and control panel

PLC control and remote monitoring subject to availability

Transfer Pump

Indicative flow range: 30–60 m³/h

Final flow based on viscosity, temperature, pressure and pipework

Connections

Flanged inlet and outlet

Nominal size and flange standard to be confirmed

Power Supply

To be confirmed for the selected model

Voltage, phase and frequency matched to site utilities

Configuration Selection Guide

 

Storage Capacity

Determine the required working volume from daily bitumen consumption, delivery intervals, reserve requirements and replenishment arrangements.

01

Mobility Structure

Choose a trailer-mounted configuration for projects requiring road transport, or a skid-mounted configuration for temporary sites with suitable lifting and positioning equipment.

02

Heating Method

Select thermal oil heating where a compatible thermal oil supply is available. Electric heating may suit sites with sufficient electrical capacity and an appropriate power supply.

03

Insulation Requirements

Specify insulation thickness according to minimum ambient temperature, target holding temperature, storage duration and acceptable heat loss.

04

Transfer System

Confirm the required discharge rate, bitumen viscosity, operating temperature, pipeline length and connection requirements before selecting the pump.

05

 

 

Manufacturing & Quality Control

Manufacturing and inspection requirements should be defined according to the tank design, heating system and applicable project specifications.
Material Verification
Material grades and supporting documentation should be checked against the approved drawings and bill of materials. Material certificates can be specified where required.
Welding Inspection
Weld preparation, welding procedures and inspection methods should follow the applicable design and fabrication requirements. Visual inspection and additional non-destructive testing can be defined in the inspection plan.
Heating System Testing
Heating coils, piping and associated components should be tested according to their design requirements and approved test procedures before commissioning.
Electrical and Control Checks
Inspection can cover sensor operation, temperature control, over-temperature protection, emergency stops and electrical connections according to the confirmed system configuration.
Documentation
Available quality records may include inspection reports, material certificates, test records and equipment documentation, subject to the agreed supply scope.
Applicable standards and certification requirements must be confirmed for the specific equipment design and destination market.

Mobile Road Construction Bitumen Tank

 

Applications & System Integration

Road Construction Projects

Provides on-site bitumen storage and transfer for paving operations where supply needs to be coordinated with construction schedules.

Mobile Asphalt Plants

Supports temporary bitumen storage and supply. Pump flow, discharge temperature and piping connections must match the plant's operating requirements.

Remote and Temporary Sites

Trailer-mounted and skid-mounted options accommodate different site access, relocation and lifting arrangements.

Bitumen Distribution and Intermediate Storage

Can serve as an intermediate storage unit between bulk deliveries and downstream processing equipment, subject to the required storage and transfer capacity.

 

 
 
Delivery, Warranty & After-Sales Support

Transport Planning

Trailer-mounted and skid-mounted units require different transport arrangements. Confirm overall dimensions, empty weight, loaded weight, lifting points and destination transport restrictions before shipment.

Packaging and Protection

Packaging and corrosion protection should be selected according to the transport method, shipping duration and destination environment.

 

Warranty and Spare Parts

Warranty coverage, spare-parts availability and technical support should be confirmed in the quotation or supply contract. Recommended spare parts can be specified according to the pump, heating and control configurations.

Installation and Commissioning

Installation guidance and commissioning requirements should be agreed before delivery, including electrical connections, external heat sources, piping and site preparation.

 

 

Request a Custom Quotation

 

Provide the following information to support technical evaluation and quotation.

 

RFQ Requirement

Information to Provide

Required Capacity

Nominal volume and required usable volume

Bitumen Grade

Penetration grade, PMB grade or other applicable specification

Heating Method

Thermal oil, electric heating or a proposed alternative

Target Temperature

Initial temperature, storage temperature and discharge temperature

Mobility Type

Trailer-mounted or skid-mounted

Site Utilities

Available voltage, phase, frequency and heating energy source

Transfer Requirements

Required flow rate, pipeline length and connection details

Destination

Country, delivery location and applicable compliance requirements

Documentation

Required standards, inspection records and certificates

Project Schedule

Required delivery date and commissioning expectations

Request a Quotation
Submit available specifications, drawings and project requirements for configuration review. Missing technical information can be confirmed during the engineering review. 

 

 

Frequently Asked Questions

 

 

Q: What is the difference between trailer-mounted and skid-mounted bitumen tanks?

A: Trailer-mounted tanks are intended for relocation using a suitable towing vehicle and a compliant road-transport configuration. Skid-mounted tanks are positioned using appropriate lifting equipment and are suitable for temporary or semi-permanent installations.

Q: Which heating method should I choose?

A: Thermal oil heating is suitable where a compatible thermal oil system is available. Electric heating may be considered where sufficient electrical capacity is available. The choice depends on tank capacity, initial temperature, target temperature, heating time and site utilities.

Q: Can a mobile bitumen tank connect to an existing asphalt plant?

A: Yes, subject to interface compatibility. Pump flow, operating temperature, piping layout, flange standards and control signals should be reviewed against the asphalt plant's requirements before ordering.

Q: What information is needed to calculate heating time?

A: The main inputs include tank capacity, actual loading volume, initial bitumen temperature, target temperature, ambient conditions, insulation specifications and available heating power. A heating-time estimate should be based on these parameters rather than heater power alone.

Q: What technical documents should be confirmed before purchase?

A: Confirm the approved technical specification, general arrangement drawing, material documentation, applicable inspection and test records, electrical documentation and any destination-specific compliance documents required by the project.

As one of the leading mobile bitumen tanks manufacturers and suppliers in China, we warmly welcome you to buy cheap mobile bitumen tanks from our factory. All customized products are with high quality and competitive price. Contact us for pricelist.

Send Inquiry